Filter Results By:

Products

Applications

Manufacturers

Showing results: 2491 - 2505 of 2632 items found.

  • Digital 10kV High Voltage Insulation Tester

    4310 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Digital 5kV High Voltage Insulation Tester

    4305 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 1 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Handheld Micro-Ohmmeters

    RMO-H Series - IBEKO Power AB

    The RMO-H is battery operated and handheld micro-ohmmeter. It is designed for a variety of applications for contact resistance measurement of non-inductive test objects. Typical applications are accurate testing of:medium and high-voltage circuit breakers,disconnecting switches,high-current bus bar joints,cable splices,and different high-current links.Even more, it accurately measures in high-induction filed environments and substations, as well as in factory testing.RMO-H Series contains six models in total, divided in 2 sub-series depending on the test leads length requirement and the battery type:RMO-H1, RMO-H2 and RMO-H3 models are intended for use with short cables (e.g. 1,3 m / 3 m / 5 m). The 1-cell Li-Po battery with 8200 mAh capacity provides output voltage up to 4,1 V DC.RMO-H21, RMO-H22 and RMO-H23 models are ideal for applications where test leads with lengths > 5 m are required. The high output voltage (up to 8,3 V DC) is provided by 2-cells 4100 mAh Li-Po battery.The test current is regulated and can be selected in a range of 1 A to maximum 300 A, depending on the maximum test current rating:RMO-H1, RMO-H21 models – up to 100 A DCRMO-H2, RMO-H22 models – up to 220 A DCRMO-H3, RMO-H23 models – up to 300 A DC.Unlike many other handheld micro-ohmmeters available on the market, our instruments have regulated and user-selectable test currents. Therefore, RMO-H instruments generate an automatically regulated test ramp with stable and ripple-free current during measurement. These revolutionary characteristics in a handheld micro-ohmmeters technology are possible by using sophisticated Li-Po batteries. Consequently, modern battery technology enables you to do multiple measurements, and a full day of testing without recharging the battery.With all RMO-H models, it is possible to make tests on Both Sides Grounded testing objects, in an increased safety environment. Finally, these features in combination with a user-friendly interface (1-click to measure) significantly speed-up testing procedure and make it safer.These instruments store up to 1000 measurements on the internal micro SD card.Our free DV Win software communicates with the RMO-H micro-ohmmeters via a wireless Bluetooth interface. Furthermore, it allows you to download test results, analysis and generate fully configurable test reports.

  • Solar Analyzers

    Meco Instruments Pvt. Ltd.,

    Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Clamp On Meters

    Triplett Test Equipment & Tools

    1000A True RMS AC/DC clamp-on meter with a backlit LCD display. It offers a large variety of measurement features including AC/DC Current, AC/DC Voltage, Resistance, Temperature, Capacitance, Continuity, Diode Test and NCV Detector. The rubberized overmolded housing provides impact and drop resistance in a sleek ergonomic design, and the user-friendly Auto Power Off feature helps maximizes battery life. With a CAT III 600V design, it provides superior resistance to damage from transient overvoltages in any demanding industrial setting. The Model 9325 is suited for a variety of industrial and residential applications such as security, electrical, HVAC installations and more. Includes test leads, Type K Temperature probe, 9V battery, and case.

  • C Series Universal Analog Input Module

    NI

    The C Series Universal Analog Input Module helps you perform multi-purpose measurements. This module includes built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. You also can choose options to measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors.The C Series Universal Analog Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Precision Current Loop Calibrator With Hart Communications

    LC-110H - Martel Calibrators

    The Martel LC-110 and LC-110H are mA (loop) calibrators designed to take the loop calibrator class to the next level. The new LC-110 series feature a user friendly interface with dedicated buttons and a rotary encoder (Quick-Set Knob). This combination drastically reduces the time it takes to measure, simulate, or source both voltage and current and power up a loop. The rugged ABS plastic case is contoured to easily fit a technician's hand and the large back lit graphics LCD is best in class. The LC-110H differs from the standard LC-110 in that it incorporates HART communications and supports a select set of the HART universal and common practice commands. This unique feature allows the LC-110H to be used as both a loop calibrator and communication tool.

  • Remote I/O

    ADLINK Technology Inc.

    ADLINK remote IO and serial communication cards are suitable for handling multiple digital signal types for IoT and other industrial applications such as facility monitoring, environmental monitoring, and industrial process control.Remote IO - NuDAM modules provide direct communication with various sensors, including performing signal conditioning, scaling, linearization and conversion to obtain temperature, pressure, flow, voltage, and current measurements. The new ND6100 series modules use Modbus/RTU remote data transmission protocols, providing customers with a comprehensive product portfolio. ADLINK's serial communication cards provide a PCI/PCIe interface and support RS-232 and CAN communication interfaces, allowing customers to choose the most suitable communication card for various automation equipment needs.

  • Converter Of Electrical Quantities

    Metra Blansko a.s.

    The converters are intended for the conversion of electrical quantities DC signal which is either in form of the DC voltage, or the DC forced current. They can be used in connection with indicating pointer instruments, calibrated in units of the measured quantity, or with a recorder or, eventually with a digital instrument. Wide range of possibilities are provided by them, also as sensors for regulation and control porposes in the fields of industrial measurements and, last but not least, as needful components for aquisition of technological enviroment picture applied for evaluating and processing computer systems. The converters are designed for continuous operation. They are designed as independent, built in the plastic casing. Each converter comprises the input circuits for the galvanic separation of the proper measuring circuit and the output amplifier for the output signal conversion to the unified output.

  • 96 Pin 1.27mm Pitch Micro-D Connector & Cable Accessories

    Pickering Interfaces Ltd.

    The 96 Pin 1.27mm Pitch Micro-D Connector is used on high-density PXI modules that require 1A current rating and voltage handling up to 150Vdc. If you would like to develop your own cabling solutions, we offer mating connectors and connector hoods that allow you to create either your own cable based solutions, or a PCB header solution. Connector Blocks directly terminate the module connector and convert the connection to arrays of screw terminal blocks, or you can select to use a remote DIN rail mounted breakout to terminate the cables at the end of a cable assembly. You can also try our Cable Design Tool to graphically design a customized cable assembly.

  • Bench/System Precision Linear Regulated DC Power Supply With Digital Control, Single Or Triple Outputs, 105 To 242 Watts, With/without Remote Interfaces

    QL Series II - Aim-TTi

    Advanced dc power supplies, single or triple outputUp to 112 watts per outputVery high precision, very low noise, excellent dynamicsAdvanced user interface with numeric and rotary controlMultiple voltage/current ranges for increased flexibilityMultiple non-volatile memories for power supply set-upsSwitchable remote sense provides perfect load regulationComprehensive protection including OVP and OCP tripsCompact bench footprint; modular width for rack mountingAuxiliary output fully variable 1.00V to 6.00V at 3A with selectable voltage and current metering (T models)Bus programmable via USB, RS232, GPIB or LAN (P models)LAN interface is LXI compliantDuplicate power and sense terminals at rear (P models)

  • Micro probes 1 MHz up to 6 GHz

    MFA 01 set - Langer EMV-Technik GmbH

    The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Micro probes 1 MHz up to 1 GHz

    MFA 02 set - Langer EMV-Technik GmbH

    The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • DC Power Supplies

    Asterion DC Series - AMETEK Programmable Power, Inc.

    The Sorensen Asterion line of DC power supplies by AMETEK Programmable Power combines intelligence and flexibility to create an advanced platform of DC solutions in 1.7, 3.4, 5.0 & 10kW. The new DC series features two types of product lines: fixed range and autoranging. The fixed range supplies are economical, traditional rectangular wave output power supplies with all the enhanced operation advantages standard with the Asterion platform. The autoranging supplies feature expanded current and voltage range at the full output power level, enabling the ability to satisfy a wider testing need without requiring the purchase of additional models. Its groundbreaking capabilities set the standard for affordable, precision power supplies.

Get Help